Capacity & Style
Balcony Seating (upper) | 138 seats, including 4 wheelchair spaces |
---|---|
Orchestra Seating (lower) | 382 seats, including 8 wheelchair spaces |
Total Capacity | 520 seats plus 12 wheelchair spaces |
Pricing
The Richard J. Ernst Community Cultural Center is in the process of updating all of its pricing. To obtain a quote, please call our office at 703.323.3159.
Stage Dimensions
Proscenium Opening: | 16'-8" high x 38'-5" wide |
---|---|
Stage Height Above Auditorium Floor: | 3'-6" |
Front Lip to Back Wall: | 34'-0" |
Front Lip to Plaster Line: | 11'-10" |
Front Lip to Act Curtain: | 13'-6" approximate |
Front Lip to Sky Drop: | 29'-8" |
Plaster Line to Back Wall: | 22'-2" |
Stage Left Wall to Proscenium Opening: | 16'-0 "x 20' high |
Stage Right Wall to Proscenium Opening: | 20'-6 x 25' high |
Orchestra Pit Cover: | 7'-10" x approximate 40" wide x 8'-6" deep |
Rigging
Fly Tower: | Approximately 46' wide and 42' high with no grid |
---|---|
Act Curtain: | red velour, manual counterweight, can be flown from stage left or traveled from stage right |
There are 12 single-speed motorized line sets controlled from a panel stage left. Batten distances upstage of the plaster line and their uses are as follows:
- 3'-3" electric #1 - down light, back light, pipe ends, work lights, upstage front light, specials
- 5 "-2" empty batten
- 6'-1" empty batten
- 7'-6" movie screen, front or rear projection 15'-6 "Hx20'-6" W
- 8'-4" empty batten
- 9'-2" full-stage black traveler curtain
- 11'-9" electric #2 – down light, back light, pipe ends, work lights, specials
- 14'-1" empty batten
- 15'-4" electric #3 – four cell L&E Broad Cyc lights, back lights
- 16'-6" empty batten
- 17'-3" full-stage black curtain (6 removable panels)
- 18'-2" full-stage white cyclorama (20'x42')
Lighting Equipment
Control Room: | Located in the center rear of the auditorium, access from house right sound lock |
---|---|
System: | ETC Element 500 |
Dimmers: | Lee Colortran ENR dual 2.4K dimmer modules in two ENR 96 racks. The system is dimmer per circuit, 192 circuits, 15 of which are house lights. |
Lighting Fixtures
(some older instruments not included)
10 | ETC Source 4 36° | Down light specials | 575 W |
30 | ETC Source 4 26° | Front lights and breakup wash | 575 W |
5 | ETC Source 4 19° (with irises) | Front light specials | 575 W |
8 | 15 to 40-degree zoom | Catwalk pipe ends | 750 W |
30 | ETC Source 4 PAR XWFL | 1st and 2nd electric down lights | 575 W |
10 | 8" Fresnel | 3rd electric back lights | 1500 W |
4 | 14" Scoops | Over stage work lights | 750 W |
6 | L&E Broad Cyc, 4 cell (RGBA) | Cyc lights | 1000 W |
20 | Altman 3.5Q | Side lights | 500 W |
18 | Strand 6x9" Ellipsoidal | Side lights and pipe ends | 500 W |
4 | ETC Source 4 Jr. zoom 26°-50° | Miscellaneous specials | 575 W |
Sound
Control: | The enclosed control booth is located at the rear of the main floor of the auditorium. |
---|---|
Systems: | There is a Telex 4-channel headset system with 6-single ear headsets and 5 belt packs. There are plugs stage left and right, in the pit, on the back wall of the auditorium, at the follow spot booths in the balcony and various other locations. There is a monitor system that can distribute sound on stage and announcements to the dressing rooms and a number of other locations. |
There is a theater sound system designed to provide quality sound to the auditorium. It consists of the following components:
- Allen & Heath GL2400 32 channel mixer
- 2 JBL MRX 500 speaker clusters floor mounted on lower level
- QSC 4050HD amp for main house speakers
- QSC 5050 amp for main house subwoofers
- 4 Shure SM 57 microphones
- 6 Shure SM 58 microphones
- 4 Shure SM-58 wireless handheld microphones
- 3 Sabine wireless handheld microphones
- 3 Sabine wireless lavalier microphones
- Denon DN-D4500 dual deck CD player
- 1/8" iPod/computer input
- TELEX/Clear-Com hybrid headset communication system. 8 Clear-Com belt packs utilizing a TELEX main receiver in the control room. Headset locations include 4 positions back stage, 2 positions in the balcony, 1 position in the orchestra seating (tech table), 1 position in the orchestra pit, control room, art galleries, dressing rooms, wardrobe, green room and scene shop.
Crossover, compressor, equalizer, patch panel, etc. together with mic inputs and speaker outputs are at several locations backstage and in the house.
Dressing Rooms
Women's: | 326 sq. ft., 2 sinks, 2 showers (1 handicapped), 1 toilet for handicapped, 26 lockers 1'x3' and 33' of make-up counter backed with lighted mirrors. Includes audio and video monitoring of stage. |
---|---|
Men's: | 243 sq. ft., 1 sink, 1 shower, 1 toilet for handicapped, 16 lockers and 28' of make-up counter backed with lighted mirrors. Includes audio and video monitoring of stage. |
Wardrobe Room: | 133 sq. ft., heavy-duty washer and dryer, counter space, ironing board and iron; there are no other costume supplies or equipment on site. Includes audio and video monitoring of stage. |
Green Room
A 256 sq. ft. room furnished with chairs, tables and audio and video monitoring of stage. It can be used as an additional dressing room.
Scene Shop
This is a 555 sq. ft. room, off-stage right adjacent to the loading door that serves as a storage room for theater equipment and incoming shows. There are no construction tools or supplies on site.
Loading Docks
Two loading docks are on the east wing (theater side) of the building. The first has a 6'6" wide by 8'2" high rolling door, provides direct access to the stage and can accommodate a 26' truck. The second loading dock has double doors and provides access to the art galleries and backstage hallways –- this dock accommodates smaller trucks, cars and vans.